Summary[edit]
A sickEngine component launches a SICK TOP in a separate process so that more than one SICK sensor can be used in the same project.
Parameters - SICK Page
Active
Active
- Activate the connection to the sensor.
LaunchFile
Launchfile
- A path to the launch file to configure the sensor. A valid launch file is necessary to connect to the sensor. Sample launch files for each sensor can be downloaded from SICK's website. Advanced configuration options can be set in the launch file.
Address
Address
- The IP address for the sensor. If this parameter is blank, the default address in the launch file will be used.
Port
Port
- The port number for the sensor. If this parameter is blank, the default port number in the launch file will be used.
Custom Arguments
Customargs
- Additional arguments that should be included when initializing the sensor. This can be used to customize parameters for individual sensors while still using the same launch file. Arguments should be in the format "name1:=value1 name2:=value2".
Red
Red
- ⊞ - The name of the data field that will be assigned to the red component of the output image e.g. 'x'. The available fields will vary depending on the sensor and can be selected from the flyout menu to the right of the parameter.
- Zero
zero
-
- One
one
-
Green
Green
- ⊞ - The name of the data field that will be assigned to the green component of the output image e.g. 'g'. The available fields will vary depending on the sensor and can be selected from the flyout menu to the right of the parameter. 'one' or 'zero' can be used to assign a constant value.
- Zero
zero
-
- One
one
-
Blue
Blue
- ⊞ - The name of the data field that will be assigned to the blue component of the output image e.g. 'z'. The available fields will vary depending on the sensor and can be selected from the flyout menu to the right of the parameter. 'one' or 'zero' can be used to assign a constant value.
- Zero
zero
-
- One
one
-
Alpha
Alpha
- ⊞ - The name of the data field that will be assigned to the alpha component of the output image e.g. 'one'. The available fields will vary depending on the sensor and can be selected from the flyout menu to the right of the parameter. 'one' or 'zero' can be used to assign a constant value.
- Zero
zero
-
- One
one
-
Parameters - About Page
Help
Help
- Click to open this help page.
Version
Version
- The version of this component.